Problem Cause Solution
Semi-trash pump will not start No fuel Add fuel
Faulty spark plug Replace spark plug
Semi-trash pump will not start; Semi-trash
pump starts but runs roughly
Low oil level Fill crankcase to the proper level; place
semi-trash pump on a flat, level surface
Choke in the wrong position Adjust choke
Spark plug wire loose Attach wire to spark plug
Semi-trash pump shuts down during
operation
Out of fuel Fill fuel tank
Low oil level Fill crankcase to the proper level; place
semi-trash pump on a flat, level surface
Semi-trash pump overheating or
performing poorly
Strainer or hose clogged Remove debris from strainer or hose
Pump not primed Re-prime pump
Suction hose out of water Place suction hose under the surface of
the water
Head limit exceeded Relocate pump so suction head is less
than discharge head (maximum 98 feet)
Air leak Tighten connectors and clamps or replace
seal packing